Easy Steps for using the BuckHook system:
- Attach a short lifeline and mobile fall arrestor to the sternal attachment on the harness. For connecting lanyards longer than 12″ a shock pack should be attached to the dorsal attachment.
- Using the extension pole with BuckHook and 7/16″ or ½” non-stretch rope attached, lift and secure hook onto lattice so that the end of the pole is below foot level.
- Once in place, climb up near BuckHook
- Secure secondary positioning lanyard around the tower leg. Once secure, move BuckHook to the next highest point making sure the end of the pole is below the user’s feet.
- Once at the worksite user should secure an anchor sling to a suitable anchorage point. The primary vertical lifeline can then be attached to the anchor sling.
- Once the lifeline is installed, other climbers can connect their harness to a mobile fall arrester and ascend and descend the lifeline.